In this practical we use
- Double acting cylinder
- 5/2-way solenoid valves
- 3 inductive proximity sensor
- relay counter
as result of this cylinder action the sensor sens and then start the other cylinder working after counting 5 stroke the two cylinder stop their action
the pneumatic diagram and electro pneumatic are below image
and working video is there